Reverse Phase and Normal Phase High end Liquid Chromatography (HPLC)

High end Liquid Chromatography (HPLC) is used being an analytical instrument to separate certain substances in a sample. The HPLC include a pump that delivers the mobile phase and sample through the system, an auto sampler or injector port for sample introduction, the stationary phase where separation of compounds takes place, a detector to detect the compounds and a good integrator or a computer system for the visible output.
If you liked this post and you would like to receive far more facts with regards to autosampler kindly take a look at our own web-page.

HPLC first started along with normal phase. Normal phase HPLC means the stationary phase is made from polar packing material while the cellular phase is of non-polar or low polarity solvents. Commonly used polar stationary phase or column is filled with silica. Silica is relatively the most polar compound compared to all other packing components. Another polar column is cyano column which has a more intermediate polarity. Examples of solvents used to make up a normal phase mobile phase are hexane, dichloromethane, chloroform, ethyl ether, plus isopropyl alcohol (IPA). Most of the solvents used in the mobile phase are usually water immiscible and have low polarity. In most cases, these solvents are used with each other in a mixture of in order to achieve compounds separation. For example , Hexane: IPA (9: 1) means the mobile phase include a mixture of hexane and IPA at the ratio of 9 to 1. In a normal phase application, the non-polar compounds will be eluted faster compared to polar compounds.

In the 1970s, invert phase HPLC was developed. The rule is opposite of normal phase system, where the stationary phase is packed non-polar material and the mobile phase is polar. Commonly used packaging material in reverse phase columns are silica linked with carbon-18 (C18). Additional columns of more intermediate polarity, such as C8 and cyano. Remember that cyano can be used in both normal plus reverse phases and some column producers produce two types of cyano line to suit each phase. The cellular phase for a reverse phase system usually consists of water or buffer solution, methanol, acetonitrile and IPA. IPA can be used in both reverse plus normal phase as it is miscible along with water as well as water immiscible solvents. However , large amount of IPA in a cellular phase will cause high pressure in the HPLC system due to its high density value. Inside a reverse phase HPLC, the non-polar compounds are retained in the line longer than the polar compounds. Within another words, the polar substances elute faster than the non-polar substances.

Leave a Reply

Your email address will not be published. Required fields are marked *